catheter
→
ReceivesAction
→
removed
|
0.78
|
|
catheter
→
ReceivesAction
→
withdrawn
|
0.77
|
|
catheter
→
ReceivesAction
→
inserted
|
0.68
|
|
catheter
→
ReceivesAction
→
inserted into vein
|
0.67
|
|
catheter
→
ReceivesAction
→
placed
|
0.66
|
|
catheter
→
ReceivesAction
→
inserted into artery
|
0.66
|
|
catheter
→
ReceivesAction
→
inserted into a blood vessel
|
0.65
|
|
catheter
→
ReceivesAction
→
inserted into the body
|
0.64
|
|
catheter
→
ReceivesAction
→
configured
|
0.62
|
|
catheter
→
ReceivesAction
→
formed
|
0.62
|
|
catheter
→
ReceivesAction
→
shown in fig
|
0.61
|
|
catheter
→
ReceivesAction
→
advanced over the guidewire
|
0.61
|
|
catheter
→
ReceivesAction
→
inserted into femoral artery
|
0.60
|
|
catheter
→
ReceivesAction
→
inserted into vessel
|
0.58
|
|
catheter
→
ReceivesAction
→
introduced
|
0.58
|
|
catheter
→
ReceivesAction
→
provided
|
0.58
|
|
catheter
→
ReceivesAction
→
inserted into femoral vein
|
0.58
|
|
catheter
→
ReceivesAction
→
inserted into the heart
|
0.57
|
|
catheter
→
ReceivesAction
→
removed after the procedure
|
0.57
|
|
catheter
→
ReceivesAction
→
examined
|
0.57
|
|
catheter
→
ReceivesAction
→
changed
|
0.57
|
|
catheter
→
ReceivesAction
→
left in place
|
0.56
|
|
catheter
→
ReceivesAction
→
prepared
|
0.55
|
|
catheter
→
ReceivesAction
→
positioned
|
0.55
|
|
catheter
→
ReceivesAction
→
inserted into right atrium
|
0.55
|
|
catheter
→
ReceivesAction
→
inserted in the groin
|
0.55
|
|
catheter
→
ReceivesAction
→
inserted into jugular vein
|
0.54
|
|
catheter
→
ReceivesAction
→
inserted through small incision
|
0.54
|
|
catheter
→
ReceivesAction
→
pulled
|
0.53
|
|
catheter
→
ReceivesAction
→
disposed
|
0.53
|
|
catheter
→
ReceivesAction
→
introduced into the patient
|
0.53
|
|
catheter
→
ReceivesAction
→
constructed
|
0.53
|
|
catheter
→
ReceivesAction
→
deployed
|
0.52
|
|
catheter
→
ReceivesAction
→
flushed
|
0.52
|
|
catheter
→
ReceivesAction
→
threaded through artery
|
0.52
|
|
catheter
→
ReceivesAction
→
advanced through the introducer…
|
0.51
|
|
catheter
→
ReceivesAction
→
introduced into artery
|
0.51
|
|
catheter
→
ReceivesAction
→
inserted into the urethra
|
0.50
|
|
catheter
→
ReceivesAction
→
inserted into left ventricle
|
0.50
|
|
catheter
→
ReceivesAction
→
connected
|
0.50
|
|
catheter
→
ReceivesAction
→
manipulated through the patient…
|
0.50
|
|
catheter
→
ReceivesAction
→
accessed at the patient's neck
|
0.50
|
|
catheter
→
ReceivesAction
→
inserted into the bladder
|
0.50
|
|
catheter
→
ReceivesAction
→
inserted into the patient
|
0.50
|
|
catheter
→
ReceivesAction
→
used in conjunction
|
0.49
|
|
catheter
→
ReceivesAction
→
known in the art
|
0.49
|
|
catheter
→
ReceivesAction
→
used to drain fluid
|
0.49
|
|
catheter
→
ReceivesAction
→
inserted into a body cavity
|
0.49
|
|
catheter
→
ReceivesAction
→
rotated
|
0.48
|
|
catheter
→
ReceivesAction
→
inserted into subclavian vein
|
0.48
|
|
catheter
→
ReceivesAction
→
employed
|
0.48
|
|
catheter
→
ReceivesAction
→
introduced into the vessel
|
0.48
|
|
catheter
→
ReceivesAction
→
retracted
|
0.48
|
|
catheter
→
ReceivesAction
→
bent
|
0.48
|
|
catheter
→
ReceivesAction
→
implanted
|
0.48
|
|
catheter
→
ReceivesAction
→
introduced into the vein
|
0.48
|
|
catheter
→
ReceivesAction
→
placed in coronary sinus
|
0.48
|
|
catheter
→
ReceivesAction
→
secured to the patient
|
0.47
|
|
catheter
→
ReceivesAction
→
sterilized
|
0.47
|
|
catheter
→
ReceivesAction
→
introduced over guidewire
|
0.47
|
|
catheter
→
ReceivesAction
→
provided with balloon
|
0.47
|
|
catheter
→
ReceivesAction
→
inflated
|
0.47
|
|
catheter
→
ReceivesAction
→
placed under the skin
|
0.47
|
|
catheter
→
ReceivesAction
→
treated
|
0.47
|
|
catheter
→
ReceivesAction
→
guided to the heart
|
0.46
|
|
catheter
→
ReceivesAction
→
secured
|
0.46
|
|
catheter
→
ReceivesAction
→
inserted in the arm
|
0.46
|
|
catheter
→
ReceivesAction
→
inserted through puncture
|
0.46
|
|
catheter
→
ReceivesAction
→
passed into the bladder
|
0.46
|
|
catheter
→
ReceivesAction
→
inserted through the skin
|
0.45
|
|
catheter
→
ReceivesAction
→
placed in coronary angiogram
|
0.45
|
|
catheter
→
ReceivesAction
→
torqued
|
0.45
|
|
catheter
→
ReceivesAction
→
described in u.s. pat
|
0.44
|
|
catheter
→
ReceivesAction
→
inserted over the guide wire
|
0.44
|
|
catheter
→
ReceivesAction
→
shown in figure
|
0.44
|
|
catheter
→
ReceivesAction
→
described
|
0.44
|
|
catheter
→
ReceivesAction
→
flushed with heparinized saline
|
0.43
|
|
catheter
→
ReceivesAction
→
kept dry
|
0.43
|
|
catheter
→
ReceivesAction
→
inserted through the sheath
|
0.43
|
|
catheter
→
ReceivesAction
→
guided
|
0.43
|
|
catheter
→
ReceivesAction
→
inserted into large vein
|
0.43
|
|
catheter
→
ReceivesAction
→
detached
|
0.42
|
|
catheter
→
ReceivesAction
→
inserted into the patient's body
|
0.42
|
|
catheter
→
ReceivesAction
→
advanced over the guide wire
|
0.42
|
|
catheter
→
ReceivesAction
→
inserted into the aorta
|
0.42
|
|
catheter
→
ReceivesAction
→
connected to a drainage bag
|
0.42
|
|
catheter
→
ReceivesAction
→
cleaned
|
0.42
|
|
catheter
→
ReceivesAction
→
filled with saline
|
0.42
|
|
catheter
→
ReceivesAction
→
adapted
|
0.41
|
|
catheter
→
ReceivesAction
→
guided through artery
|
0.41
|
|
catheter
→
ReceivesAction
→
threaded through the blood vess…
|
0.41
|
|
catheter
→
ReceivesAction
→
fixed
|
0.41
|
|
catheter
→
ReceivesAction
→
secured to the skin
|
0.41
|
|
catheter
→
ReceivesAction
→
extended
|
0.41
|
|
catheter
→
ReceivesAction
→
guided through the blood vessel
|
0.41
|
|
catheter
→
ReceivesAction
→
adapted for insertion
|
0.40
|
|
catheter
→
ReceivesAction
→
connected to the pump
|
0.40
|
|
catheter
→
ReceivesAction
→
positioned within a body lumen
|
0.40
|
|
catheter
→
ReceivesAction
→
replaced
|
0.40
|
|
catheter
→
ReceivesAction
→
inserted through the needle
|
0.40
|
|
catheter
→
ReceivesAction
→
accessed
|
0.40
|
|
catheter
→
ReceivesAction
→
drawn
|
0.40
|
|
catheter
→
ReceivesAction
→
threaded into the heart
|
0.40
|
|
catheter
→
ReceivesAction
→
used in patient
|
0.40
|
|
catheter
→
ReceivesAction
→
packaged
|
0.40
|
|
catheter
→
ReceivesAction
→
advanced into the heart
|
0.39
|
|
catheter
→
ReceivesAction
→
passed into artery
|
0.39
|
|
catheter
→
ReceivesAction
→
passed over the guide wire
|
0.39
|
|
catheter
→
ReceivesAction
→
pushed
|
0.39
|
|
catheter
→
ReceivesAction
→
manufactured
|
0.39
|
|
catheter
→
ReceivesAction
→
withdrawn over the guidewire
|
0.39
|
|
catheter
→
ReceivesAction
→
described in detail
|
0.39
|
|
catheter
→
ReceivesAction
→
introduced into the body
|
0.39
|
|
catheter
→
ReceivesAction
→
operated
|
0.39
|
|
catheter
→
ReceivesAction
→
disclosed
|
0.39
|
|
catheter
→
ReceivesAction
→
allowed to dry at ambient tempe…
|
0.38
|
|
catheter
→
ReceivesAction
→
closed
|
0.38
|
|
catheter
→
ReceivesAction
→
connected to the port
|
0.38
|
|
catheter
→
ReceivesAction
→
inserted into major vein
|
0.38
|
|
catheter
→
ReceivesAction
→
threaded through vein
|
0.38
|
|
catheter
→
ReceivesAction
→
kept clean
|
0.38
|
|
catheter
→
ReceivesAction
→
introduced into venous system
|
0.38
|
|
catheter
→
ReceivesAction
→
guided to desired location
|
0.38
|
|
catheter
→
ReceivesAction
→
manipulated
|
0.38
|
|
catheter
→
ReceivesAction
→
guided through vein
|
0.38
|
|
catheter
→
ReceivesAction
→
inserted into vascular system o…
|
0.38
|
|
catheter
→
ReceivesAction
→
inserted over the guidewire
|
0.38
|
|
catheter
→
ReceivesAction
→
placed at exact site
|
0.38
|
|
catheter
→
ReceivesAction
→
positioned in the vein
|
0.38
|
|
catheter
→
ReceivesAction
→
threaded over the guidewire
|
0.38
|
|
catheter
→
ReceivesAction
→
used to administer medication
|
0.38
|
|
catheter
→
ReceivesAction
→
advanced through the vasculature
|
0.37
|
|
catheter
→
ReceivesAction
→
extracted
|
0.37
|
|
catheter
→
ReceivesAction
→
passed over the guidewire
|
0.37
|
|
catheter
→
ReceivesAction
→
placed in epidural space
|
0.37
|
|
catheter
→
ReceivesAction
→
studied
|
0.37
|
|
catheter
→
ReceivesAction
→
threaded
|
0.37
|
|
catheter
→
ReceivesAction
→
inserted through the introducer…
|
0.37
|
|
catheter
→
ReceivesAction
→
advanced against resistance
|
0.36
|
|
catheter
→
ReceivesAction
→
expanded
|
0.36
|
|
catheter
→
ReceivesAction
→
held
|
0.36
|
|
catheter
→
ReceivesAction
→
moved into position
|
0.36
|
|
catheter
→
ReceivesAction
→
separated
|
0.36
|
|
catheter
→
ReceivesAction
→
inserted in chest
|
0.36
|
|
catheter
→
ReceivesAction
→
used to deliver fluid
|
0.36
|
|
catheter
→
ReceivesAction
→
deflected
|
0.36
|
|
catheter
→
ReceivesAction
→
exchanged
|
0.36
|
|
catheter
→
ReceivesAction
→
intended for peripheral vascula…
|
0.36
|
|
catheter
→
ReceivesAction
→
pulled in proximal direction
|
0.36
|
|
catheter
→
ReceivesAction
→
advanced into the patient
|
0.35
|
|
catheter
→
ReceivesAction
→
introduced into the blood vessel
|
0.35
|
|
catheter
→
ReceivesAction
→
proposed
|
0.35
|
|
catheter
→
ReceivesAction
→
used to deliver device
|
0.35
|
|
catheter
→
ReceivesAction
→
lubricated
|
0.35
|
|
catheter
→
ReceivesAction
→
used in connection
|
0.35
|
|
catheter
→
ReceivesAction
→
used to inject dye
|
0.35
|
|
catheter
→
ReceivesAction
→
moved
|
0.34
|
|
catheter
→
ReceivesAction
→
advanced through a blood vessel
|
0.34
|
|
catheter
→
ReceivesAction
→
anchored
|
0.34
|
|
catheter
→
ReceivesAction
→
delivered into targeted vein
|
0.34
|
|
catheter
→
ReceivesAction
→
implanted for localized and tar…
|
0.34
|
|
catheter
→
ReceivesAction
→
inserted into duct
|
0.34
|
|
catheter
→
ReceivesAction
→
inserted into luman
|
0.34
|
|
catheter
→
ReceivesAction
→
kept sterile
|
0.34
|
|
catheter
→
ReceivesAction
→
placed at the treatment site
|
0.34
|
|
catheter
→
ReceivesAction
→
placed in specific areas
|
0.34
|
|
catheter
→
ReceivesAction
→
positioned in the vessel
|
0.34
|
|
catheter
→
ReceivesAction
→
sized
|
0.34
|
|
catheter
→
ReceivesAction
→
advanced into the vein
|
0.34
|
|
catheter
→
ReceivesAction
→
advanced over the needle
|
0.34
|
|
catheter
→
ReceivesAction
→
advanced over wire
|
0.34
|
|
catheter
→
ReceivesAction
→
advanced through inferior vena …
|
0.34
|
|
catheter
→
ReceivesAction
→
attached to the barrier
|
0.34
|
|
catheter
→
ReceivesAction
→
clamped
|
0.34
|
|
catheter
→
ReceivesAction
→
deformed
|
0.34
|
|
catheter
→
ReceivesAction
→
designed to be left within organ
|
0.34
|
|
catheter
→
ReceivesAction
→
directed
|
0.34
|
|
catheter
→
ReceivesAction
→
guided into coronary artery
|
0.34
|
|
catheter
→
ReceivesAction
→
inserted through small cut
|
0.34
|
|
catheter
→
ReceivesAction
→
maneuvered
|
0.34
|
|
catheter
→
ReceivesAction
→
positioned for deployment of th…
|
0.34
|
|
catheter
→
ReceivesAction
→
released
|
0.34
|
|
catheter
→
ReceivesAction
→
slid over the guide wire
|
0.34
|
|
catheter
→
ReceivesAction
→
advanced into left ventricle
|
0.33
|
|
catheter
→
ReceivesAction
→
advanced into side-branch vessel
|
0.33
|
|
catheter
→
ReceivesAction
→
cleared
|
0.33
|
|
catheter
→
ReceivesAction
→
connected to light source
|
0.33
|
|
catheter
→
ReceivesAction
→
connected to machine
|
0.33
|
|
catheter
→
ReceivesAction
→
cut
|
0.33
|
|
catheter
→
ReceivesAction
→
designed for single use
|
0.33
|
|
catheter
→
ReceivesAction
→
inserted into position
|
0.33
|
|
catheter
→
ReceivesAction
→
inserted through the pfo tunnel
|
0.33
|
|
catheter
→
ReceivesAction
→
placed in the treatment site ba…
|
0.33
|
|
catheter
→
ReceivesAction
→
tracked over the guidewire
|
0.33
|
|
catheter
→
ReceivesAction
→
heated
|
0.32
|
|
catheter
→
ReceivesAction
→
inserted into the uterus
|
0.32
|
|
catheter
→
ReceivesAction
→
introduced at antecubital fossa
|
0.32
|
|
catheter
→
ReceivesAction
→
reinserted
|
0.32
|
|
catheter
→
ReceivesAction
→
used in combination
|
0.32
|
|
catheter
→
ReceivesAction
→
broken
|
0.32
|
|
catheter
→
ReceivesAction
→
advanced beyond the bifurcation
|
0.31
|
|
catheter
→
ReceivesAction
→
coated
|
0.31
|
|
catheter
→
ReceivesAction
→
cut to appropriate length
|
0.31
|
|
catheter
→
ReceivesAction
→
disposed in main lumen
|
0.31
|
|
catheter
→
ReceivesAction
→
excised
|
0.31
|
|
catheter
→
ReceivesAction
→
filled
|
0.31
|
|
catheter
→
ReceivesAction
→
folded into a u-shape
|
0.31
|
|
catheter
→
ReceivesAction
→
inserted into the leg
|
0.31
|
|
catheter
→
ReceivesAction
→
inserted through the wrist
|
0.31
|
|
catheter
→
ReceivesAction
→
introduced into right atrium
|
0.31
|
|
catheter
→
ReceivesAction
→
left in case
|
0.31
|
|
catheter
→
ReceivesAction
→
locked
|
0.31
|
|
catheter
→
ReceivesAction
→
passed into vein
|
0.31
|
|
catheter
→
ReceivesAction
→
placed into the channel
|
0.31
|
|
catheter
→
ReceivesAction
→
pressurized
|
0.31
|
|
catheter
→
ReceivesAction
→
reused
|
0.31
|
|
catheter
→
ReceivesAction
→
routed through the vascular sys…
|
0.31
|
|
catheter
→
ReceivesAction
→
used to place second anastomoti…
|
0.31
|
|
catheter
→
ReceivesAction
→
blocked
|
0.30
|
|
catheter
→
ReceivesAction
→
advanced to desired location
|
0.30
|
|
catheter
→
ReceivesAction
→
caused by contraction of the he…
|
0.30
|
|
catheter
→
ReceivesAction
→
caused to pierce septum primum
|
0.30
|
|
catheter
→
ReceivesAction
→
coated with same drug
|
0.30
|
|
catheter
→
ReceivesAction
→
configured for introduction
|
0.30
|
|
catheter
→
ReceivesAction
→
configured to detect cardiac ac…
|
0.30
|
|
catheter
→
ReceivesAction
→
connected to fluid source
|
0.30
|
|
catheter
→
ReceivesAction
→
connected to the generator
|
0.30
|
|
catheter
→
ReceivesAction
→
connected to the manifold
|
0.30
|
|
catheter
→
ReceivesAction
→
controlled
|
0.30
|
|
catheter
→
ReceivesAction
→
coupled to distal end
|
0.30
|
|
catheter
→
ReceivesAction
→
delivered to desired location
|
0.30
|
|
catheter
→
ReceivesAction
→
dipped in solution
|
0.30
|
|
catheter
→
ReceivesAction
→
exchanged over the guidewire
|
0.30
|
|
catheter
→
ReceivesAction
→
extruded
|
0.30
|
|
catheter
→
ReceivesAction
→
formed into loop
|
0.30
|
|
catheter
→
ReceivesAction
→
guided to right side of the hea…
|
0.30
|
|
catheter
→
ReceivesAction
→
held by a catheter mount
|
0.30
|
|
catheter
→
ReceivesAction
→
inserted into endotracheal tube
|
0.30
|
|
catheter
→
ReceivesAction
→
inserted into intrathecal space
|
0.30
|
|
catheter
→
ReceivesAction
→
inserted into large blood vessel
|
0.30
|
|
catheter
→
ReceivesAction
→
inserted into the esophagus
|
0.30
|
|
catheter
→
ReceivesAction
→
inserted through small hole
|
0.30
|
|
catheter
→
ReceivesAction
→
inserted through the valve body
|
0.30
|
|
catheter
→
ReceivesAction
→
inserted to desired location
|
0.30
|
|
catheter
→
ReceivesAction
→
left inside the body
|
0.30
|
|
catheter
→
ReceivesAction
→
passed through the nose
|
0.30
|
|
catheter
→
ReceivesAction
→
passed to the blockage
|
0.30
|
|
catheter
→
ReceivesAction
→
placed by surgeon
|
0.30
|
|
catheter
→
ReceivesAction
→
placed in the ventricle
|
0.30
|
|
catheter
→
ReceivesAction
→
positioned at the site of the d…
|
0.30
|
|
catheter
→
ReceivesAction
→
reached the target site
|
0.30
|
|
catheter
→
ReceivesAction
→
received by the bolus tip
|
0.30
|
|
catheter
→
ReceivesAction
→
received in the working channel
|
0.30
|
|
catheter
→
ReceivesAction
→
tested
|
0.30
|
|
catheter
→
ReceivesAction
→
used to insert stent
|
0.30
|
|
catheter
→
ReceivesAction
→
used to pace the heart
|
0.30
|
|
catheter
→
ReceivesAction
→
used to place drug
|
0.30
|
|
catheter
→
ReceivesAction
→
deflated
|
0.29
|
|
catheter
→
ReceivesAction
→
imaged
|
0.29
|
|
catheter
→
ReceivesAction
→
implanted in the brain
|
0.29
|
|
catheter
→
ReceivesAction
→
moved through the lesion
|
0.29
|
|
catheter
→
ReceivesAction
→
positioned for deployment of th…
|
0.29
|
|
catheter
→
ReceivesAction
→
provided by the manufacturer
|
0.29
|
|
catheter
→
ReceivesAction
→
removed intact
|
0.29
|
|
catheter
→
ReceivesAction
→
secured to the base
|
0.29
|
|
catheter
→
ReceivesAction
→
removed in the office
|
0.28
|
|
catheter
→
ReceivesAction
→
activated
|
0.27
|
|
catheter
→
ReceivesAction
→
advanced into patient's coronar…
|
0.27
|
|
catheter
→
ReceivesAction
→
collapsed
|
0.27
|
|
catheter
→
ReceivesAction
→
compressed
|
0.27
|
|
catheter
→
ReceivesAction
→
connected to reservoir
|
0.27
|
|
catheter
→
ReceivesAction
→
coupled to an angioplasty press…
|
0.27
|
|
catheter
→
ReceivesAction
→
coupled to cryogenic fluid supp…
|
0.27
|
|
catheter
→
ReceivesAction
→
cured in oven
|
0.27
|
|
catheter
→
ReceivesAction
→
designed for recording intracar…
|
0.27
|
|
catheter
→
ReceivesAction
→
designed for temporary pacing
|
0.27
|
|
catheter
→
ReceivesAction
→
dimensioned in embodiment
|
0.27
|
|
catheter
→
ReceivesAction
→
dried
|
0.27
|
|
catheter
→
ReceivesAction
→
inserted into the trachea
|
0.27
|
|
catheter
→
ReceivesAction
→
inserted through the cervix
|
0.27
|
|
catheter
→
ReceivesAction
→
inserted through the iv
|
0.27
|
|
catheter
→
ReceivesAction
→
integrated as one member
|
0.27
|
|
catheter
→
ReceivesAction
→
irrigated
|
0.27
|
|
catheter
→
ReceivesAction
→
mounted to the retainer
|
0.27
|
|
catheter
→
ReceivesAction
→
passed through the endoscope
|
0.27
|
|
catheter
→
ReceivesAction
→
peeled
|
0.27
|
|
catheter
→
ReceivesAction
→
placed by interventional radiol…
|
0.27
|
|
catheter
→
ReceivesAction
→
placed in the artery and contra…
|
0.27
|
|
catheter
→
ReceivesAction
→
removed through tortuous path
|
0.27
|
|
catheter
→
ReceivesAction
→
stripped
|
0.27
|
|
catheter
→
ReceivesAction
→
used to deliver agent
|
0.27
|
|
catheter
→
ReceivesAction
→
withdrawn into right atrium
|
0.27
|
|
catheter
→
ReceivesAction
→
withdrawn into the cranial vena…
|
0.27
|
|
catheter
→
ReceivesAction
→
displaced
|
0.25
|
|
catheter
→
ReceivesAction
→
adapted to include a sensing lu…
|
0.25
|
|
catheter
→
ReceivesAction
→
advanced over the guide element
|
0.25
|
|
catheter
→
ReceivesAction
→
advanced through circulatory sy…
|
0.25
|
|
catheter
→
ReceivesAction
→
advanced with the cutting eleme…
|
0.25
|
|
catheter
→
ReceivesAction
→
aligned over the groove
|
0.25
|
|
catheter
→
ReceivesAction
→
assembled in advance of inserti…
|
0.25
|
|
catheter
→
ReceivesAction
→
attached to a urine bag
|
0.25
|
|
catheter
→
ReceivesAction
→
available in several charriere …
|
0.25
|
|
catheter
→
ReceivesAction
→
blocked by sediment
|
0.25
|
|
catheter
→
ReceivesAction
→
capped
|
0.25
|
|
catheter
→
ReceivesAction
→
coated with silver alloy
|
0.25
|
|
catheter
→
ReceivesAction
→
coiled
|
0.25
|
|
catheter
→
ReceivesAction
→
configured for retrograde deplo…
|
0.25
|
|
catheter
→
ReceivesAction
→
connected by member 30
|
0.25
|
|
catheter
→
ReceivesAction
→
connected to one side of the bo…
|
0.25
|
|
catheter
→
ReceivesAction
→
connected to recorder
|
0.25
|
|
catheter
→
ReceivesAction
→
connected to tubing
|
0.25
|
|
catheter
→
ReceivesAction
→
dimensioned
|
0.25
|
|
catheter
→
ReceivesAction
→
directed to intravascular locat…
|
0.25
|
|
catheter
→
ReceivesAction
→
engaged
|
0.25
|
|
catheter
→
ReceivesAction
→
equipped with high frequency
|
0.25
|
|
catheter
→
ReceivesAction
→
equipped with ultraminiature
|
0.25
|
|
catheter
→
ReceivesAction
→
exchanged for one of a differen…
|
0.25
|
|
catheter
→
ReceivesAction
→
expelled
|
0.25
|
|
catheter
→
ReceivesAction
→
exposed to wetting fluid
|
0.25
|
|
catheter
→
ReceivesAction
→
externalized
|
0.25
|
|
catheter
→
ReceivesAction
→
fed through contralateral femor…
|
0.25
|
|
catheter
→
ReceivesAction
→
filled with bhi
|
0.25
|
|
catheter
→
ReceivesAction
→
forced
|
0.25
|
|
catheter
→
ReceivesAction
→
free of metallic radiomarker me…
|
0.25
|
|
catheter
→
ReceivesAction
→
immobilized
|
0.25
|
|
catheter
→
ReceivesAction
→
implanted in carotid artery
|
0.25
|
|
catheter
→
ReceivesAction
→
impregnated with antibiotic
|
0.25
|
|
catheter
→
ReceivesAction
→
impregnated with rifampin
|
0.25
|
|
catheter
→
ReceivesAction
→
inserted for long distances
|
0.25
|
|
catheter
→
ReceivesAction
→
inserted in similar fashion
|
0.25
|
|
catheter
→
ReceivesAction
→
inserted into arthroscopic tool…
|
0.25
|
|
catheter
→
ReceivesAction
→
inserted into axillary artery
|
0.25
|
|
catheter
→
ReceivesAction
→
inserted into cystic duct
|
0.25
|
|
catheter
→
ReceivesAction
→
inserted into pulmonary artery
|
0.25
|
|
catheter
→
ReceivesAction
→
inserted through the penetratio…
|
0.25
|
|
catheter
→
ReceivesAction
→
inserted with surgical drape
|
0.25
|
|
catheter
→
ReceivesAction
→
interconnected with electrical …
|
0.25
|
|
catheter
→
ReceivesAction
→
introduced through conventional…
|
0.25
|
|
catheter
→
ReceivesAction
→
joined through an injection mol…
|
0.25
|
|
catheter
→
ReceivesAction
→
knotted
|
0.25
|
|
catheter
→
ReceivesAction
→
loaded into sheath 20
|
0.25
|
|
catheter
→
ReceivesAction
→
measured using the swab extract…
|
0.25
|
|
catheter
→
ReceivesAction
→
moved in said first direction
|
0.25
|
|
catheter
→
ReceivesAction
→
placed in ostium
|
0.25
|
|
catheter
→
ReceivesAction
→
placed upon the shaft
|
0.25
|
|
catheter
→
ReceivesAction
→
positioned at the site of the c…
|
0.25
|
|
catheter
→
ReceivesAction
→
positioned in renal artery
|
0.25
|
|
catheter
→
ReceivesAction
→
positioned under fluoroscopic o…
|
0.25
|
|
catheter
→
ReceivesAction
→
provided with a deflection wire
|
0.25
|
|
catheter
→
ReceivesAction
→
purchased
|
0.25
|
|
catheter
→
ReceivesAction
→
reached the aneurysm
|
0.25
|
|
catheter
→
ReceivesAction
→
removed as unit
|
0.25
|
|
catheter
→
ReceivesAction
→
replaced with sleeve
|
0.25
|
|
catheter
→
ReceivesAction
→
secured with suture
|
0.25
|
|
catheter
→
ReceivesAction
→
secured within the channel
|
0.25
|
|
catheter
→
ReceivesAction
→
shown having radio-opaque band
|
0.25
|
|
catheter
→
ReceivesAction
→
split
|
0.25
|
|
catheter
→
ReceivesAction
→
started
|
0.25
|
|
catheter
→
ReceivesAction
→
stored
|
0.25
|
|
catheter
→
ReceivesAction
→
taken out after the angiogram
|
0.25
|
|
catheter
→
ReceivesAction
→
unclamped
|
0.25
|
|
catheter
→
ReceivesAction
→
used to deliver diagnostic, the…
|
0.25
|
|
catheter
→
ReceivesAction
→
used to guide tiny electrodes
|
0.25
|
|
catheter
→
ReceivesAction
→
used to infuse drug
|
0.25
|
|
catheter
→
ReceivesAction
→
used to place small mesh tube
|
0.25
|
|
catheter
→
ReceivesAction
→
used to place various treatment…
|
0.25
|
|
catheter
→
ReceivesAction
→
used until graft
|
0.25
|
|
catheter
→
ReceivesAction
→
used with process
|
0.25
|
|
catheter
→
ReceivesAction
→
viewed under -ray fluoroscopy
|
0.25
|
|
catheter
→
ReceivesAction
→
viewed under aid
|
0.25
|
|
catheter
→
ReceivesAction
→
withdrawn as fig
|
0.25
|
|
catheter
→
ReceivesAction
→
easy to use
|
0.24
|
|
catheter
→
ReceivesAction
→
damaged
|
0.22
|
|
catheter
→
ReceivesAction
→
positioned within tortuous vess…
|
0.22
|
|
catheter
→
ReceivesAction
→
frozen to the tissue
|
0.20
|
|
catheter
→
ReceivesAction
→
contaminated
|
0.16
|
|
catheter
→
ReceivesAction
→
destroyed
|
0.16
|
|
catheter
→
ReceivesAction
→
inserted for drainage of ascites
|
0.16
|
|
catheter
→
ReceivesAction
→
recalled
|
0.16
|
|
catheter
→
ReceivesAction
→
stored in pocket
|
0.16
|
|
catheter
→
ReceivesAction
→
used in our case
|
0.16
|
|
catheter
→
ReceivesAction
→
biased
|
0.09
|
|