Assertion list for term "leaflet".

Results from Ascent++: 56
leaflet (aspect of valve) ReceivesActionshown in fig 0.52
leaflet (aspect of valve) ReceivesActionattached to the frame 0.50
leaflet (aspect of valve) ReceivesActionmounted within a peripheral support structure 0.50
leaflet (aspect of valve) CapableOfcome into contact 0.47
leaflet (aspect of valve) ReceivesActionconstrained within crimped frame 0.46
leaflet (aspect of valve) HasAsize 0.43
leaflet (aspect of valve) ReceivesActionattached to the cuff 0.43
leaflet (aspect of valve) ReceivesActionremoved 0.41
leaflet (aspect of valve) ReceivesActioncut 0.40
leaflet (aspect of valve) ReceivesActionformed of pericardial tissue 0.40
leaflet (aspect of valve) ReceivesActionprovided as porcine 0.38
leaflet (aspect of valve) ReceivesActionprovided as bovine 0.38
leaflet (aspect of valve) ReceivesActionmounted 0.38
leaflet (aspect of valve) ReceivesActionsewn to component 0.38
leaflet (aspect of valve) ReceivesActionshown 0.38
aortic valve (subgroup of valve) HasAleaflet 0.35
leaflet (aspect of valve) CapableOffunction as a one-way valve 0.34
leaflet (aspect of valve) CapableOfuse percutaneous method 0.34
leaflet (aspect of valve) HasAarcuate cusp edge 0.34
leaflet (aspect of valve) ReceivesActionpositioned 0.34
leaflet (aspect of valve) ReceivesActionmounted to the stent posts 0.34
leaflet (aspect of valve) ReceivesActionsutured 0.34
leaflet (aspect of valve) CapableOfcreate orifice 0.30
leaflet (aspect of valve) CapableOfoverlap one another 0.30
leaflet (aspect of valve) HasAcentral area 0.30
leaflet (aspect of valve) HasPropertysymmetric 0.30
leaflet (aspect of valve) ReceivesActionprovided independent of one another 0.30
leaflet (aspect of valve) ReceivesActionfolded 0.30
leaflet (aspect of valve) ReceivesActionattached to the stent 0.30
leaflet (aspect of valve) ReceivesActioncompressed 0.30
leaflet (aspect of valve) ReceivesActionconnected to each other 0.30
leaflet (aspect of valve) ReceivesActionspread 0.30
leaflet (aspect of valve) ReceivesActionattached to the annulus 0.30
leaflet (aspect of valve) ReceivesActiondisposed along inside wall of the vein 0.30
leaflet (aspect of valve) CapableOfprevent blood 0.25
leaflet (aspect of valve) CapableOfflow in only one direction 0.25
leaflet (aspect of valve) CapableOfimpede reverse flow of blood 0.25
leaflet (aspect of valve) CapableOfdiffer in size 0.25
leaflet (aspect of valve) CapableOfdescribed in u.s. pat 0.25
leaflet (aspect of valve) CapableOfblock the lumen of the vessel 0.25
leaflet (aspect of valve) HasAfree edge 0.25
leaflet (aspect of valve) MadeOfpolymeric materials 0.25
leaflet (aspect of valve) ReceivesActionfabricated at same time 0.25
leaflet (aspect of valve) ReceivesActionattached to the mitral valve annulus 0.25
leaflet (aspect of valve) ReceivesActionconnected to the anchoring structure 0.25
leaflet (aspect of valve) ReceivesActiontested 0.25
leaflet (aspect of valve) ReceivesActionattached in natural configuration 0.25
leaflet (aspect of valve) ReceivesActiontransferred to the grasper 0.25
leaflet (aspect of valve) ReceivesActionattached to external wall 0.25
leaflet (aspect of valve) ReceivesActioncaptured 0.25
leaflet (aspect of valve) ReceivesActionformed with first extracellular matrix material 0.25
leaflet (aspect of valve) ReceivesActionattached around the leaflet frame 0.25
leaflet (aspect of valve) ReceivesActionattached along their belly portions 0.25
leaflet (aspect of valve) ReceivesActionattached to panel 0.25
leaflet (aspect of valve) CapableOffunction at different level 0.16
leaflet (aspect of valve) HasSubeventmitral regurgitation 0.16