Assertion list for term "stent".

Results from Ascent++: 706
stent ReceivesActionexpanded 0.78
stent ReceivesActionpositioned 0.75
stent ReceivesActiondeployed 0.74
stent ReceivesActionremoved 0.73
stent HasPropertyexpandable 0.73
stent ReceivesActionformed 0.72
stent CapableOfremain in place 0.72
stent ReceivesActionplaced 0.70
coronary stent (subgroup of stent) HasAexpanded diameter 0.68
ureteral stent (subgroup of stent) ReceivesActionimplanted 0.68
stent MadeOfstainless steel 0.67
stent ReceivesActionplaced in the artery 0.66
medical device (subgroup of device) ReceivesActionstent 0.66
stent ReceivesActionshown in fig 0.65
stent MadeOfmetal 0.64
stent ReceivesActionleft in place 0.64
stent ReceivesActioncompressed 0.64
stent ReceivesActiondesigned 0.64
stent HasAdiameter 0.63
stent IsAsmall mesh tube 0.63
stent ReceivesActioninserted 0.63
stent ReceivesActionfabricated 0.61
ureteral stent (subgroup of stent) ReceivesActionshown in fig 0.61
ureteral stent (subgroup of stent) ReceivesActionplaced within a body of a patient 0.61
stent ReceivesActionconstructed 0.61
stent CapableOfkeep the artery 0.60
stent ReceivesActioncoated with medicine 0.60
stent ReceivesActionimplanted in bodily vessel 0.60
stent MadeOfnitinol 0.60
stent HasPropertytubular 0.59
stent ReceivesActionexpanded to larger diameter 0.59
stent ReceivesActionmade 0.59
stent HasAlength 0.58
stent ReceivesActionmounted on a balloon catheter 0.58
stent IsAsmall tube 0.58
stent CapableOfrestore blood flow 0.58
stent ReceivesActionimplanted 0.58
stent ReceivesActionopened 0.57
stent HasPropertyflexible 0.57
stent HasPropertycylindrical 0.57
stent HasPropertypermanent 0.56
stent ReceivesActionknown in the art 0.55
stent MadeOfplastic 0.55
ureteral stent (subgroup of stent) ReceivesActionconfigured to facilitate the movement of fluid 0.55
stent ReceivesActionreleased 0.54
stent ReceivesActionput in place 0.54
stent ReceivesActiondelivered to desired location 0.53
stent CapableOfact as scaffold 0.53
stent ReceivesActioncoated with polymer 0.53
stent ReceivesActionproduced 0.52
stent CapableOfimprove blood flow 0.52
stent ReceivesActioncut 0.52
stent ReceivesActionreplaced 0.52
stent ReceivesActionimplanted in luman 0.52
stent MadeOfpolymer 0.52
stent CapableOfbe a combination of both 0.52
stent HasAtubular shape 0.52
stent ReceivesActiondelivered 0.52
stent MadeOfmaterial 0.51
stent ReceivesActionloaded 0.51
stent CapableOfremain in the artery 0.50
stent ReceivesActionadvanced 0.50
stent ReceivesActionused in patient 0.50
stent ReceivesActioncomposed of network 0.49
stent ReceivesActionused in the vascular system 0.49
stent HasAabove-described coating 0.49
stent CapableOfprevent restenosis 0.49
stent ReceivesActionpositioned on the balloon 0.49
stent HasAproximal end 0.48
stent ReceivesActionrequired 0.48
stent ReceivesActioncrimped 0.48
stent IsAa wire mesh tube 0.48
stent ReceivesActiondisposed on the balloon 0.48
stent MadeOfmetal mesh 0.48
stent CapableOfkeep the blood vessel 0.48
stent ReceivesActionconfigured to maintain expanded state 0.48
stent ReceivesActionimplanted in the esophagus 0.48
stent ReceivesActionplaced inside the artery 0.48
stent ReceivesActionleft in the artery 0.48
stent IsAtube 0.47
stent ReceivesActionintroduced 0.47
stent ReceivesActionheld in place 0.47
stent HasPropertydistal 0.47
stent ReceivesActioninserted into the body 0.47
stent MadeOftitanium 0.47
stent ReceivesActionshown in figure 0.46
stent ReceivesActionconfigured 0.46
stent CapableOfprovide structural support 0.46
stent ReceivesActionmounted on the balloon 0.46
stent ReceivesActionsecured to the catheter 0.46
stent HasPropertyunnecessary 0.46
stent AtLocationexpanded configuration 0.46
stent HasAinitial crimped outer diameter 0.45
stent HasAcircular cross 0.45
stent HasPropertyto be positioned proximal 0.45
stent ReceivesActioncovered with neointima 0.45
stent ReceivesActiondeployed in the artery 0.45
stent CapableOfcomprise tubular body 0.45
stent ReceivesActioninserted into a blood vessel 0.45
stent ReceivesActionexpanded at desired area of treatment 0.45
stent ReceivesActionexpanded with single expansion 0.45
stent CapableOfmaintain vascular patency 0.45
stent ReceivesActiondelivered on balloon 0.45
stent ReceivesActiondescribed 0.44
stent MadeOfwire mesh 0.44
stent CapableOfuse catheter 0.44
stent ReceivesActiondisclosed in u.s. pat 0.44
stent ReceivesActionplaced in coronary artery 0.44
stent ReceivesActiondeformed 0.44
device ReceivesActionstent 0.44
stent ReceivesActionused in the treatment of atherosclerotic stenosis 0.44
stent MadeOfbiocompatible plastic 0.44
stent ReceivesActionused in india 0.44
stent ReceivesActioncovered 0.44
stent HasPropertybent 0.44
stent CapableOfhelp support inner wall of the artery 0.44
stent ReceivesActionused to keep artery 0.44
stent ReceivesActiondelivered to the treatment site 0.43
stent ReceivesActiondescribed in u.s. pat 0.43
stent HasAexpanded state 0.43
stent HasAdistal end 0.43
stent ReceivesActionplaced in vessel 0.43
stent HasPropertyuseful 0.43
stent HasPropertyelectropolished 0.43
stent HasAlongitudinal axis 0.43
stent ReceivesActionmounted on expandable member 0.43
stent ReceivesActionattached to the graft 0.43
stent CapableOfprevent the artery 0.43
invention RelatedTostent 0.42
stent ReceivesActionused in europe 0.42
stent ReceivesActionleft in the ureter 0.42
stent ReceivesActionimplanted in artery 0.42
stent ReceivesActionplaced in the ureter 0.42
stent ReceivesActionattached 0.42
stent ReceivesActiondeployed at the treatment site 0.42
stent ReceivesActionplaced in case 0.42
stent CapableOfkeep the vessel 0.41
stent ReceivesActioncollapsed 0.41
stent CapableOfrefer to fig 0.41
stent HasPropertysmall 0.41
stent HasAscaffolding 0.41
stent HasAunexpanded state 0.41
stent ReceivesActioncontracted 0.41
stent ReceivesActioninflated 0.41
stent ReceivesActionequipped with one or more barbs 0.41
stent MadeOfsilicone material 0.41
stent ReceivesActionused to prop open artery 0.41
stent HasPropertylarge 0.41
stent HasPropertymore flexible 0.41
stent HasPropertyrigid 0.41
stent CapableOfopen the artery 0.41
stent CapableOfexpand to larger diameter 0.41
stent CapableOfmaintain blood flow 0.41
coronary stent (subgroup of stent) ReceivesActionplaced in coronary arteries 0.41
stent HasPropertyradiolucent 0.40
stent ReceivesActionplaced in wide array of blood vessels 0.40
stent ReceivesActionreduced in diameter 0.40
stent CapableOfrelease drug 0.40
stent ReceivesActionused in conjunction 0.40
stent Causesinfection 0.40
stent ReceivesActionselected 0.40
stent CapableOfremain in the body 0.40
stent ReceivesActionabsorbed 0.40
stent HasPropertybioabsorbable 0.40
stent HasPropertylong 0.40
stent ReceivesActionprevented 0.40
stent CapableOfimprove angioplasty results 0.40
stent CapableOfwithstand greater radial force 0.40
stent ReceivesActionextended 0.40
stent ReceivesActionexposed 0.40
stent ReceivesActiondried 0.40
stent ReceivesActioncoated with paclitaxel 0.40
stent IsAa metal or plastic tube 0.39
stent ReceivesActionrotated 0.39
stent HasPropertybiodegradable 0.39
stent ReceivesActionpositioned in the target area 0.39
stent ReceivesActionblocked 0.39
stent ReceivesActionused with present invention 0.39
stent CapableOfprevent a heart attack 0.39
stent CapableOfexpand to the size of the artery 0.39
stent ReceivesActiondamaged 0.39
stent ReceivesActionplaced in narrowed artery 0.39
stent CapableOfreinforce the vessel walls 0.39
catheter HasAstent 0.38
stent HasPropertyproblematic 0.38
stent HasPropertyeffective 0.38
stent HasAy-shaped structure 0.38
stent ReceivesActionmounted onto a balloon angioplasty catheter 0.38
stent HasPropertyidentical 0.38
stent ReceivesActionpositioned in main vessel 0.38
stent MadeOfalloy 0.38
stent ReceivesActionmade in accordance 0.38
stent CapableOfcomprise a stent body 0.38
stent CapableOfremain in the vessel 0.38
stent ReceivesActionimplanted in urinary tract 0.38
stent ReceivesActionexpanded into contact 0.38
stent ReceivesActionmoved through the catheter 0.38
stent ReceivesActionmounted 0.38
stent ReceivesActionsecured 0.38
stent HasPropertyradiopaque 0.38
stent MadeOfelgiloy 0.37
stent CapableOfallow for normal blood flow 0.37
stent ReceivesActionextended within the vessel 0.37
stent ReceivesActionlocked into place 0.37
stent HasPropertyimplantable 0.37
stent MadeOfa superelastic nickel titanium alloy 0.37
stent ReceivesActionformed of biocompatible material 0.37
stent HasAshape 0.37
stent ReceivesActionimplanted in the bifurcation 0.37
stent ReceivesActionretrieved 0.37
stent ReceivesActionexpanded to second diameter 0.37
stent ReceivesActionuncovered 0.37
stent CapableOfcomprise a deformable material 0.37
stent ReceivesActiondeployed within vessel 0.37
stent ReceivesActionfixed 0.37
implant ReceivesActionstent 0.37
stent ReceivesActionplaced in the bile duct 0.37
stent HasPropertybiocompatible 0.36
stent HasPropertycollapsible 0.36
stent CapableOfprovide unobstructed conduit 0.36
stent ReceivesActioncollapsed to small diameter 0.36
stent CapableOfsatisfy several mechanical requirements 0.36
stent CapableOfwithstanding the structural loads 0.36
stent ReceivesActionadapted 0.36
stent CapableOfhelp keep coronary artery 0.36
stent ReceivesActiondeployed in a body lumen 0.36
stent CapableOfprevent future blockages 0.36
stent MadeOfa shape memory alloy 0.36
stent CapableOfsupport the artery 0.36
stent AtLocationcollapsed configuration 0.36
stent CapableOfserve to hold open the artery 0.36
stent ReceivesActionpressed into the wall of the artery 0.36
stent ReceivesActionapproved by the fda 0.36
stent CapableOfhold the graft 0.36
stent IsAballoon-expandable slotted metal tubes 0.36
stent HasPropertystrong 0.36
stent ReceivesActionmounted onto inflatable balloon 0.36
stent ReceivesActiondilated 0.36
stent ReceivesActiondislodged 0.36
stent HasPropertyadjacent 0.36
stent HasPropertyright 0.36
stent HasAmain body 0.36
stent HasAfirst end 0.36
stent ReceivesActionused to treat dissection 0.36
stent ReceivesActionused to treat aneurysm 0.36
stent ReceivesActionaligned 0.36
stent ReceivesActionapplied in ptca procedures 0.36
stent HasPropertyremovable 0.36
stent ReceivesActionflexed in use 0.36
stent HasAcompressed configuration 0.36
stent ReceivesActionpinched 0.36
stent ReceivesActionattached to a stem portion 0.36
stent ReceivesActionplaced within a body of a patient 0.36
stent CapableOfreduce the chance 0.36
stent HasAvalve 0.36
stent CapableOfprovide desired radial force 0.36
stent HasAdifferent characteristics 0.36
stent ReceivesActioncontained 0.36
stent ReceivesActionmoved 0.35
stent HasPropertysafe 0.35
stent ReceivesActioncovered with dacron 0.35
stent ReceivesActionpulled 0.35
stent CapableOfsurround the graft 0.35
stent HasAcentral lumen 0.35
stent HasPropertycompressible 0.35
stent ReceivesActionplaced in their blocked artery 0.35
stent ReceivesActionbraided 0.35
stent CapableOfextend into main-vessel 0.35
stent ReceivesActionmoved in linear direction 0.35
stent HasAdrug 0.35
stent CapableOfcarry therapeutic substance 0.35
stent HasAa side opening 0.35
stent ReceivesActionmounted on inner tube 0.35
stent ReceivesActionplaced in vein 0.35
stent HasAa side hole 0.35
stent HasApattern 0.35
stent ReceivesActionpreferred for use 0.35
stent HasPropertytemporary 0.35
stent ReceivesActionpositioned across the lesion 0.35
stent HasAseveral drawbacks 0.35
coronary stent (subgroup of stent) MadeOfmedical-grade stainless steel 0.34
coronary stent (subgroup of stent) CapableOfkeep artery 0.34
stent ReceivesActioncooled 0.34
stent ReceivesActionpushed 0.34
stent CapableOfrelieve symptom 0.34
stent ReceivesActionsubjected to stress 0.34
stent ReceivesActionplaced in blocked area 0.34
stent CapableOfcomprise second end 0.34
stent ReceivesActiondescribed in greater detail 0.34
stent HasAsubstrate 0.34
stent CapableOftake on many different patterns 0.34
stent MadeOfthe type 0.34
stent HasAthickness 0.34
stent MadeOfthe like 0.34
stent CapableOfgrab the clot 0.34
stent ReceivesActionsubjected to temperature 0.34
stent MadeOfradiopaque material 0.34
stent CapableOfexpand to predetermined diameter 0.34
stent IsAsmall plastic tube 0.34
stent HasPropertyinternal 0.34
stent CapableOfcomprise helical coil 0.34
stent ReceivesActionweighed 0.34
stent CapableOfsay less than about 25 percent 0.34
stent CapableOfrelieve chest pain 0.34
stent HasPropertyshort 0.34
stent MadeOfniti 0.34
stent CapableOfrefer as balloon expandablestents 0.33
stent CapableOfmaintain patency of the vessel 0.32
stent CapableOfopen the blockage 0.32
stent ReceivesActionresheathed 0.32
stent CapableOfcomprise a side branch structure 0.32
stent MadeOfsuperelastic nitinol 0.32
stent HasPropertyless flexible 0.32
stent CapableOfprevent the vessel 0.32
stent HasAat least one segment 0.32
stent ReceivesActionused in a variety of other applications 0.32
stent ReceivesActionplaced at the site 0.32
stent CapableOftreat coronary artery disease 0.32
stent HasAfirst smaller diameter 0.32
stent ReceivesActionencased within the wall 0.32
stent IsAtiny metal mesh tubes 0.32
stent ReceivesActionused to support intraluminal wall 0.32
stent HasAluman 0.32
stent ReceivesActioninserted into duct 0.32
stent ReceivesActionprotected by sheath 0.32
stent ReceivesActionremoved in the office 0.32
stent ReceivesActionimplanted in the side branch 0.32
stent AtLocationdistal end of the sheath 0.32
stent CapableOfmounted thereon 0.32
stent CapableOfuse fluoroscopy 0.32
stent HasAself-expanding frame 0.32
stent ReceivesActioncontrolled 0.32
stent CapableOfact as mechanical intervention 0.32
stent ReceivesActionexpanded at the site of vascular injury 0.32
stent ReceivesActionincorporated into the device 0.32
stent ReceivesActioncreated 0.32
stent ReceivesActionattached to some of the tubular member 0.32
stent ReceivesActionloaded onto the mandrel 0.32
stent ReceivesActioncompressed at low temperature 0.32
stent MadeOfmalleable material 0.32
stent ReceivesActionapposed 0.32
stent ReceivesActionheated 0.32
stent CapableOfcomprise elongate element 0.32
stent CapableOfcomprise biostable and/or biodegradable polymer 0.32
stent CapableOfcomprise a plurality of expandable rings 0.32
stent MadeOfnickel titanium alloy 0.32
stent HasPropertyvisible 0.32
stent ReceivesActioninserted through small incision 0.31
stent ReceivesActionremoved at follow-up office visit 0.31
stent ReceivesActioncollapsed around balloon 0.31
stent ReceivesActionguided through the artery 0.31
stent HasAtwo ends 0.31
stent CapableOfexpand polyethylene 0.31
stent ReceivesActiondeflated 0.31
stent ReceivesActioninflated with balloon 0.31
stent CapableOfcomprise frame 0.31
stent ReceivesActionsterilized with heat 0.31
stent HasAat least two deformable 0.31
stent HasAexpandable tubular graft members 0.31
stent IsAcylinder-like tube 0.31
stent CapableOfcounteract disease-induced, localized flow constriction 0.31
stent CapableOfexpand against the vessel wall 0.31
stent ReceivesActionimplanted at desired location of treatment 0.31
stent ReceivesActiondesigned to be coupled to bilateral grafts 0.31
stent ReceivesActioncoated with sirolimus 0.31
stent ReceivesActionplaced across native valve 0.31
stent HasAsufficient strength 0.31
stent ReceivesActionsecured by suture 0.31
stent ReceivesActiondescribed with reference 0.31
stent ReceivesActionrepositioned 0.31
stent ReceivesActionomitted for clarity 0.31
stent ReceivesActionguided to appropriate location 0.31
stent ReceivesActionemployed in prosthesis 0.31
stent HasAprosthetic graft layer of fabric 0.31
stent ReceivesActionendothelialized 0.31
stent CapableOfleave in the artery 0.31
stent CapableOfrelieve obstruction 0.31
stent ReceivesActionused to treat narrow or weak arteries 0.31
stent CapableOfopen blocked arteries 0.31
stent CapableOfseparate the aneurysm 0.31
stent ReceivesActionplaced over the lacey 0.31
stent CapableOfpressed against the vessel wall 0.31
stent CapableOfmaintain the integrity of the passageway 0.31
stent CapableOfwiden the vessel 0.31
stent HasAa plurality of leaflets 0.31
stent CapableOfcomprise a metal base ring 0.31
stent AtLocationsecond stent diameter 0.31
stent MadeOfcylindrical self-expanding member 0.31
stent IsAforeign object 0.31
stent ReceivesActionloaded onto the stent holder 0.31
stent CapableOfserve to keep luman 0.31
stent HasPropertyunexpanded 0.31
stent CapableOfdefine proximal opening 0.31
stent CapableOfextend through the myocardium 0.31
stent ReceivesActionimpinged by the pulse trains 0.31
stent ReceivesActiondisposed at angle 0.31
stent CapableOfbecome dislodged 0.30
stent ReceivesActionsewn to tubular material 0.29
stent ReceivesActionadvanced over guidewire 0.29
stent ReceivesActioninserted into a natural passage/conduit 0.29
stent CapableOfretain the shape of the mandrel 0.29
stent ReceivesActionplaced around deflated balloon 0.29
stent ReceivesActionpassed over the wire 0.29
stent ReceivesActiondyed 0.29
stent HasPropertyhollow 0.29
stent ReceivesActionsubjected to compressive forces 0.29
stent CapableOfbecome available 0.29
stent ReceivesActionreached critical deployment point 0.29
stent ReceivesActionprovided with second leg 0.29
stent HasAelement 0.29
stent ReceivesActiondisposed around a base substrate 0.29
stent ReceivesActionembedded within second segment 0.29
stent ReceivesActioncontained in medical device containment area 0.29
stent CapableOfexpand the wall of the passageway 0.29
stent CapableOfdrain the bile 0.29
stent CapableOfexpand as the sheath 0.29
stent ReceivesActioncompressed onto the balloon 0.29
stent HasPropertyconformable 0.29
stent HasAsidewall 0.29
stent ReceivesActionperfused with blood 0.29
stent ReceivesActioncoated with high molecular weight plla 0.29
stent HasAhydrophilic surface 0.29
stent HasSubeventconstant stent cell area 0.29
stent ReceivesActiondisposed on main branch balloon 0.29
stent ReceivesActionintroduced into the blood vessel 0.29
stent HasSubeventsuboptimal results 0.29
stent ReceivesActionreferred as slotted stents 0.28
stent CapableOfsave life 0.28
stent ReceivesActionbalanced for uniform expansion 0.27
stent ReceivesActionemplaced in region 0.27
stent CapableOfexpand unconstrained 0.27
stent CapableOfextend in longitudinal direction 0.27
stent HasPropertyelastic 0.27
stent ReceivesActionmounted on the deployment means 0.27
stent ReceivesActionmounted on intermediate cylindrical member 0.27
stent ReceivesActionmoved through the delivery lumen 0.27
stent ReceivesActioncoated with heparin 0.27
stent CapableOfavoid externally-protruding component parts 0.27
stent CapableOfcover branch 0.27
stent HasPropertymovable 0.27
stent ReceivesActionmanufactured as unitary braided filament structure 0.27
stent ReceivesActionarranged 0.27
stent ReceivesActionformed by laser 0.27
stent CapableOfcomprise flexible self-expandable braided tubular wall 0.27
stent ReceivesActionanchored in place 0.27
stent HasAa zig-zag configuration 0.27
stent ReceivesActionintroduced into biological environment 0.27
stent ReceivesActionguided to the site 0.27
stent HasPropertyresorbable 0.27
stent ReceivesActionplaced at junction 0.27
stent CapableOfreleased at desired control rate 0.27
stent ReceivesActioninserted into the passageway 0.27
stent ReceivesActionfree to expand 0.27
stent ReceivesActionfolded 0.27
stent HasAcross-sectional area 0.27
stent HasPropertysolid 0.27
stent CapableOfstabilize the plaque 0.27
stent CapableOfoverlay entire circumference of the ostium 0.27
stent CapableOfrotate at about 120 rpm 0.27
stent ReceivesActionmoved at about 1 mm 0.27
stent CapableOfdefine cylindrical volume 0.27
stent ReceivesActionappreciated 0.27
stent HasAmandrel 0.27
stent HasPropertyunderexpanded 0.27
stent CapableOfreconstruct the vascular path 0.27
stent CapableOfdissolve over time 0.27
stent ReceivesActioncovered with endothelial cell growth 0.27
stent HasAgap 0.27
stent ReceivesActionplaced within flexible hose 0.27
stent ReceivesActionplaced across the aneurysm neck 0.27
stent CapableOfaddress problem 0.27
stent CapableOfinduce non-specific tissue injury 0.27
stent ReceivesActionloaded with beneficial agent 0.27
stent CapableOfact as a delivery platform 0.27
stent ReceivesActionshown for clarity 0.27
stent CapableOfreduce intraocular pressure 0.27
stent ReceivesActionadapted to form flexible, cylindrical sleeve 0.27
stent ReceivesActiondisposed within the chamber 0.27
stent ReceivesActionmaintained in martensitic state 0.27
stent ReceivesActionpositioned in the chamber 0.27
stent HasAflared or conical annulus section 0.27
stent HasAless-bulbous aortic section 0.27
stent HasAshaped transition section 0.27
stent CapableOfuse infrared radiation 0.27
stent CapableOfuse microwave radiation 0.27
stent CapableOfuse high voltage polymerization 0.27
stent HasAelongate pre-coiled configuration 0.27
stent AtLocationunexpanded configuration 0.27
stent ReceivesActionaligned within the aorta 0.27
stent CapableOfexpand the graft 0.27
stent CapableOfpenetrate into native vessel 0.27
stent HasAstent mounting portion 0.27
stent ReceivesActiondisposed at the position of the lesion 0.27
stent CapableOfact as virtual ground 0.27
stent CapableOfinterconnected cylindrical rings 0.27
stent ReceivesActionseparated by three arcuate webs 0.27
stent HasAconnection points 0.27
stent ReceivesActionretained in first configuration 0.27
stent CapableOfdefine distal opening 0.27
stent HasAcentral axis 0.27
stent ReceivesActiontested at one time 0.27
stent ReceivesActionadapted to exhibit a percent reduction 0.27
stent ReceivesActiondesigned to deliver therapeutic agent 0.27
stent CapableOfexpand in the tube 0.27
stent HasAa network of stent struts 0.27
stent ReceivesActioncleaned in ultrasonic bath of isopropyl alcohol 0.27
stent HasPropertysimple 0.27
stent ReceivesActioninserted at same time 0.26
stent HasAsignificant shortcomings 0.26
stent ReceivesActionprone to fracture 0.26
stent ReceivesActionprone to high recurrence rates 0.26
stent ReceivesActionprone to treatment of hard, calcified lesions 0.26
stent CapableOfcoated with composition 0.25
stent ReceivesActionpositioned at the point of narrowing 0.25
stent ReceivesActionopened up to predetermined width 0.25
stent ReceivesActiondisengaged 0.25
stent ReceivesActionfed through curved blood vessel 0.25
stent CapableOfextend in circumferential direction 0.25
stent CapableOfadapt to the contours of the vessel 0.25
stent CapableOfexpand urethane 0.25
stent ReceivesActionpushed through the long guide sheath 0.25
stent ReceivesActionmodified to comprise one or more reservoirs 0.25
stent ReceivesActionrejected by associated costs 0.25
stent ReceivesActionsterilized with radiation 0.25
stent ReceivesActionpackaged in sterile container 0.25
stent CapableOfenable easy delivery 0.25
stent ReceivesActionkept at low temperatures 0.25
stent HasAmartensite 0.25
stent CapableOfplay vital role 0.25
stent CapableOfcover the lesion 0.25
stent ReceivesActionused per patient 0.25
stent CapableOfprovide increased access 0.25
stent CapableOfencompass same area 0.25
stent CapableOfcarry polymeric carrier 0.25
stent CapableOfcarry radioactive isotope 0.25
stent HasAangles of 45-55 degrees 0.25
stent MadeOftantalum 0.25
stent ReceivesActionheld in close radial proximity 0.25
stent ReceivesActionapproved in europe 0.25
stent ReceivesActionextruded 0.25
stent CapableOfclear passage 0.25
stent ReceivesActioninserted through the endoscope 0.25
stent ReceivesActionexchanged for new one 0.25
stent ReceivesActioncovered with everolimus 0.25
stent CapableOfopen to fit the size of the artery 0.25
stent ReceivesActionplaced into occurring space 0.25
stent CapableOfrealign the surfaces of the bones 0.25
stent HasAa diameter of 3.5 mm 0.25
stent CapableOfcomprise a first 0.25
stent CapableOfheparinize 50/50 poly-d 0.25
stent MadeOfsteel 0.25
stent HasPropertyabsorbable 0.25
stent HasAslit 0.25
stent HasPrerequisiteless force 0.25
stent ReceivesActiondesigned to remain endoluminal 0.25
stent CapableOfallow complete urothelial re 0.25
stent CapableOfimprove outcome 0.25
stent ReceivesActionrolled 0.25
stent CapableOfopen the vessel 0.25
stent ReceivesActionreleased upon expansion of the balloon 0.25
stent ReceivesActionplaced inside canal 0.25
stent AtLocationrelaxed state 0.25
stent ReceivesActiondelivered in the most beneficial location 0.25
stent ReceivesActionretained by way of example 0.25
stent ReceivesActionprovided with first leg 55 0.25
stent ReceivesActionoccluded 0.25
stent ReceivesActionplaced over tubular graft 0.25
stent ReceivesActionvisualized 0.25
stent CapableOfadvance to location 0.25
stent ReceivesActiondisposed about distal region 0.25
stent ReceivesActionetched 0.25
stent ReceivesActionto be shaped in the event 0.25
stent ReceivesActiondesigned for the trachea 0.25
stent CapableOfretain open passage 0.25
stent ReceivesActionpassed 0.25
stent ReceivesActionused in superficial femoral artery 0.25
stent CapableOfprovide protection 0.25
stent ReceivesActionplaced at texas health presbyterian hospital 0.25
stent ReceivesActionset in apposition 0.25
stent ReceivesActionadapted to expand to 3.5 mm 0.25
stent ReceivesActionused in first surgery 0.25
stent CapableOfprevent stroke 0.25
stent ReceivesActionlikely to migrate 0.25
stent ReceivesActioninterposed 0.25
stent CapableOfcomprise a plurality of cylindrical elements 0.25
stent ReceivesActionmodified to increase the number of wires 0.25
stent CapableOfdecrease the number of wires 0.25
stent CapableOfrotate within the retention device 0.25
stent HasSubevententanglement of the stent's struts 0.25
stent ReceivesActionstitched 0.25
stent CapableOfengage the occlusion/lumen wall 0.25
stent CapableOfextend into hepatic vein 0.25
stent AtLocationdesired site 0.25
stent CapableOfreach desired position 0.25
stent ReceivesActiontailored for insertion 0.25
stent AtLocationcontracted delivery configuration 0.25
stent ReceivesActionimplanted within the eye 0.25
stent ReceivesActionprefabricated 0.25
stent CapableOfoperate in environment 0.25
stent ReceivesActionplated with gold 0.25
stent ReceivesActiondisposed within sheath 0.25
stent CapableOfcome off the delivery catheter 0.25
stent CapableOfcomprise first and second support members 0.25
stent ReceivesActionviewed as flat pattern 0.25
stent ReceivesActionformed of synthetic polymers 0.25
stent ReceivesActionformed of biopolymer 0.25
stent ReceivesActionincluded in the graft mid 0.25
stent HasAstring 0.25
stent ReceivesActiondepicted in drawing 0.25
stent ReceivesActiondivided into zone 0.25
stent ReceivesActiontailored to anatomical lumens 0.25
stent CapableOfallow for phase transformations of the material 0.25
stent HasPropertyannular 0.25
stent ReceivesActionprovided with memorized shape 0.25
stent CapableOfmake frictional contact 0.25
stent MadeOfsingle length of a filament 0.25
stent CapableOfsurround inner tube 0.25
stent ReceivesActionrecommended to open blockage 0.25
stent HasPropertycurvilinear 0.25
stent CapableOfexert outward pressure 0.25
stent ReceivesActionmanufactured by direct laser cutting 0.25
stent CapableOfuse focused laser beam 0.25
stent CapableOftreat stenosis 0.25
stent ReceivesActionturned inside-out 0.25
stent ReceivesActionexpanded by the balloon catheter 0.25
stent ReceivesActionmounted on a delivery system 0.25
stent ReceivesActionviewed with fluoroscope 0.25
stent ReceivesActionplaced by dr. midei 0.25
stent ReceivesActionfinished in one of the following ways 0.25
stent ReceivesActioncovered by scar tissue 0.25
stent ReceivesActioninserted into schlemm's canal 0.25
stent CapableOfsupport trabecular meshwork 0.25
stent CapableOfrelease the agent 0.25
stent ReceivesActionprinted on site 0.25
stent CapableOfsit on chargeable section 0.25
stent ReceivesActionsupported by the mandrel 0.25
stent CapableOfcome in differing diameters 0.25
stent CapableOfcome in gauge 0.25
stent ReceivesActioninserted into clogged artery 0.25
stent ReceivesActionformed of integral unitary metal cylinder 0.25
stent ReceivesActionused to repair diseased or damaged arterial wall 0.25
stent ReceivesActionimplanted without prior angioplasty 0.25
stent ReceivesActionformed with constant wall thickness 0.25
stent ReceivesActioncoated with a paclitaxel/polymer mix 0.25
stent ReceivesActionreinforced with mechanical means 0.25
stent ReceivesActiondisposed about inner member 0.25
stent CapableOfdefine a flow path therebetween 0.25
stent HasAabove-described patterned sheath 0.25
stent ReceivesActionsupported by the stent fixture 0.25
stent ReceivesActionshown in exploded view 0.25
stent ReceivesActioncoated with dexamethasone 0.25
stent CapableOfform seal 0.25
stent ReceivesActioncaptured 0.25
stent ReceivesActionadapted to curve up to 180° 0.25
stent ReceivesActionplaced under axial load 0.25
stent HasAa plurality of commissure features 0.25
stent CapableOfhold open the tricuspid valve 0.25
stent HasAnon-collapsing lattice structure 0.25
stent ReceivesActionreleased for self-expanding stents 0.25
stent ReceivesActionplaced over the plaque 0.25
stent ReceivesActioninterlocked onto the core member 0.25
stent CapableOfcorrespond to predetermined length of the tube 0.25
stent ReceivesActionimpregnated with four anti-cancer drugs 0.25
stent ReceivesActionaffixed to flexible bridge 0.25
coronary stent (subgroup of stent) CapableOfvary in length 0.25
coronary stent (subgroup of stent) IsAtube-shaped device 0.25
ureteral stent (subgroup of stent) ReceivesActionmoved via the pusher 0.25
ureteral stent (subgroup of stent) ReceivesActionremoved 0.25
ureteral stent (subgroup of stent) ReceivesActionused after endoscopic inspection of the ureter 0.25
ureteral stent (subgroup of stent) IsAsoft plastic tube 0.25
ureteral stent (subgroup of stent) HasAhydrophilic surface 0.25
stent ReceivesActionplaced in pancreatic duct 0.22
stent ReceivesActionleft in the liver 0.22
stent ReceivesActionlost 0.20
stent CapableOfbecome clogged 0.19
stent Causesbleeding 0.19
stent CapableOfbecoming stuck inside the catheter 0.19
stent CapableOfdevelop over a period of time 0.19
stent CapableOfreplace with different device of correct size 0.19
stent ReceivesActiondescribed in the foregoing publication 0.19
stent HasPropertyexpensive 0.19
stent CapableOftreat diseased vessels 0.19
stent CapableOfbecome overgrown 0.16
stent ReceivesActionclosed 0.16
stent CapableOfirritate the bladder 0.16
stent ReceivesActionused to ensure drainage of urine 0.16
stent ReceivesActionclogged after 3 months 0.16
stent ReceivesActiondelivered through tortuous vessel 0.16
stent ReceivesActiondelivered to vascular site 0.16
stent HasSubeventsurgery-related complications 0.16
stent ReceivesActionused with great amount of success 0.16
stent ReceivesActionplaced in an artery experience stent restenosis 0.16
stent CapableOfimprove quality of life 0.16
stent CapableOfincorporate a beta emitter 0.16
stent CapableOfprovide significant early and sustained reduction 0.16
stent ReceivesActionfractured 0.16
stent HasPropertyuncomfortable 0.16
stent CapableOfexperience large length changes 0.16
stent CapableOfshift within the vessel 0.16
stent CapableOfbecome loose 0.16
stent CapableOfelute pimecrolimus 0.16
stent ReceivesActionoverused 0.16
stent ReceivesActioncoated with low molecular weight 0.16
stent CapableOflook great 0.16
stent Causespain 0.10
stent ReceivesActionimplanted in the ps group 0.09